CellFacĀ® Multi-Layer Cell Culture System

CellFacĀ® Multi-Layer Cell Culture System

Specification: 1 layerĀ  Ā 2Ā layersĀ  Ā 5 layersĀ  Ā 10 layersĀ  Ā 20 layersĀ  Ā 40 layers
Cap Type: Plug SealĀ  Ā  Vent
Surface:Ā  N-TC-treated, L-TC-treated, TC-treated, S-TC-treated CS-treatedĀ 

Product Information

The Cell Factory is a multi-layer cell culture vessel featuring a large surface area for cell growth and high cell yield in a single batch. It is widely used for large-scale cell culture and the production of various biological products.
Following years of process optimization and repeated validation, Jet Biofil’s CellFacĀ® Cell Factory has been newly upgraded! The upgraded manufacturing process delivers enhanced flatness, improved sealing performance, and more uniform, stable surface treatment, ensuring each cell factory provides more stable structure and superior cell growth surface. Working with end users, we have explored the culture characteristics of over 20 cell lines and developed 4 types of commonly required surfaces for cell process applications. We also offer customized surface solutions for different cell culture surfaces to fully meet the diverse process needs of our customers. Third-party validated final products offer ultra-low levels of extractables and high biosafety, with a complete package of validation documents available.

Hydrophobic vent cap, plug seal cap and conversion cap are available, which could satisfy different lab requirements

Cell factory (Large-mouth Molded Ports)

Cell factory (Large-mouth Embedded Ports)

Cell factory (Small-mouth Molded Ports)

CellFacĀ® Multi-Layer Cell Culture System Features

Features
Made of medical-grade PS in a specialized Class ISO 7 cleanroom
5 surface types, 3 structural and various specifications available to meet diverse application scenarios
More uniform and stable surface treatment process ensures the optimal surface for large-scale cell culture
100% online full inspection to ensure that each cell factory has high flatness and high sealing performance
Sterilized by irradiation, SAL 10-6, DNase/RNase-free, non-pyrogenic, non-cytotoxic
Features
Advanced ultrasonic welding technology offers high mechanical strength while significantly reducing the risk of leaching
Large channels inside the vessel for faster fluid balance
Customizable surfaces, structures, and tubing for various cell processes
Individually sterile-packaged with product batch numbers on each bottle bottom and packaging bag for easy quality traceability
Extremely low extractable levels and excellent biosafety, with complete package of validation documents available

Material

Bottle

Polystyrene (PS)

Bottle Cap

High-density Polyethylene (HDPE)

Filter Membrane

Polytetrafluoroethylene (PTFE)

Conforming to USP Class VI standards

Order Information

Cell and Tissue Culture Flasks , Non-treated

Cell and Tissue Culture Flasks, TC-treated

Cat. No.Volume(mL)Culture Surface Area(cm²)Type of CapRecommended Working Volume(mL)Maximum Working Volume(mL)Length(mm)Width(mm)Height(mm)Botte Neck Diameter(mm)SterileQty. Per BagQty. Per Case
TCF0110252512.5Plug Seal2.5-3.88.073.740.422.814.2Y10200
TCF0120252512.5Vent2.5-3.88.073.740.422.814.2Y10200
TCF0110505025.0Plug Seal5.0-7.517.592.949.529.118.2Y10200
TCF0120505025.0Vent5.0-7.517.592.949.529.118.2Y10200
TCF01125025075.0Plug Seal15.0-22.560.0152.581.535.225.0Y5100
TCF01225025075.0Vent15.0-22.560.0152.581.535.225.0Y5100
TCF011150375150.0 (U-shaped)Plug Seal30.0-45.0140.0199.7111.3111.325.6Y550
TCF022150375150.0 (U-shaped)Vent30.0-45.0140.0199.7111.3111.325.6Y550
TCF011175600175.0Plug Seal35.0-52.5250.0199.9122.749.225.7Y550
TCF012175600175.0Vent35.0-52.5250.0199.9122.749.225.7Y550
TCF011600600182.0Plug Seal36.4-54.6125.0219.3115.738.329.5Y540
TCF012600600182.0Vent36.4-54.6125.0219.3115.738.329.5Y540
TCF111600600182.0 (Extended)Plug Seal36.4-54.6200.0219.3115.749.529.5Y540
TCF112600600182.0 (Extended)Vent36.4-54.6200.0219.3115.749.529.5Y540
TCF011225850225.0Plug Seal60.0-90.0400.0221.9137.249.525.7Y525
TCF012225850225.0Vent60.0-90.0400.0221.9137.249.525.7Y525
TCF011850850300.0Plug Seal60.0-90.0200.0269.2166.047.029.5Y318
TCF012850850300.0Vent60.0-90.0200.0269.2166.047.029.5Y318

CellATTACHĀ® Cell and Tissue Culture Flasks

Cat. No.Volume(mL)Culture Surface Area(cm²)Type of CapMaximum Working Volume(mL)Length(mm)Width(mm)Height(mm)Botte Neck Diameter(mm)SterileQty. Per BagQty. Per Case
TCF0010252512.5Plug Seal8.073.740.422.814.2Y10200
TCF0020252512.5Vent8.073.740.422.814.2Y10200
TCF0010505025.0Plug Seal17.592.949.529.118.2Y10200
TCF0020505025.0Vent17.592.949.529.118.2Y10200
TCF00125025075.0Plug Seal60.0152.581.535.225.0Y5100
TCF00225025075.0Vent60.0152.581.535.225.0Y5100
TCF001150375150.0 (U-shaped)Plug Seal140.0199.7111.3111.325.6Y58
TCF002150375150.0 (U-shaped)Vent140.0199.7111.3111.325.6Y550
TCF001175600175.0Plug Seal250.0199.9122.749.225.7Y550
TCF002175600175.0Vent250.0199.9122.749.225.7Y550
TCF001600600182.0Plug Seal125.0219.3115.738.329.5Y540
TCF002600600182.0Vent125.0219.3115.738.329.5Y540
TCF101600600182.0 (Extended)Plug Seal200.0219.3115.749.529.5Y540
TCF102600600182.0 (Extended)Vent200.0219.3115.749.529.5Y540
TCF001225850225.0Plug Seal400.0221.9137.249.525.7Y525
TCF002225850225.0Vent400.0221.9137.249.525.7Y525
TCF001850850300.0Plug Seal200.0269.2166.047.029.5Y318
TCF002850850300.0Vent200.0269.2166.047.029.5Y318

Frequently Asked Questions

Size information of commonly used microwell plates?
The well plate size of this series conforms to ANSI/SBS well plate size standard, American National Standards Institute (ANSI ) and Society for Biomolecular Sciences (SBS, now affiliated to the Society for Laboratory Automation and Screening ( SLAS))
What is the chemical resistance of microwell plate?
In general, well plates are used for solution and cell culture. If organic solvents are involved, please confirm and verify the well plates according to the specific material of its before use.
What is the range of centrifugal force that the microwell plate can withstand?
We recommend that the centrifugal force not exceed 1,300 g. If there are other treatments affecting the mechanical strength of the well plate before centrifugation, the above suggestions may not be applicable. Please test and verify before use.
Does the deep well plate can be applied to cell culture?
It’s mainly used for sample treatment and preservation. The surface made of polypropylene has not been treated, and we have not tested it for cell culture. So it is recommended that you pre-test for specific applications and conditions before conducting relevant experiments.