CellATTACH® Cell and Tissue Culture Products

Cell and Tissue Culture Flasks:T12.5  T25  T75  T182  T300
Cap Style:Plug Seal  Vent
Cell and Tissue Culture Plates: 6-well  12-well  24-well  48-well  96-well
Cell and Tissue Culture Dishes :35 mm   60 mm   70 mm   90 mm   100 mm   150 mm

Product Information

The CellATTACH® superhydrophilic cell culture product series is created by introducing polar groups onto their surfaces. This forms a durable and stable superhydrophilic surface that facilitates good adherent growth of various types of cells under different culture conditions, thereby improving cell yield. The treated surface also eliminates the need for unstable, time-consuming, and costly biological coating.

No content in refrence need to add or need to remove in this

Unidirectional lid fits snugly with the plate body, features a condensation ring for ventilation, and prevents contamination or loss of culture medium

Raised well rims prevent cross-contamination of samples, labeled and numbered for easy left side, top side, and well-to-well identification

96-well Solid Black/White Cell Culture Plates Features

Features
Unique super-hydrophilic surface treatment technology provides better adherence for cells, promoting rapidly cell growth and increasing yields
This ensures continuous and uniform cell adherence, and can be used for adherent cultures of primary cells, neuronal cells, stem cells and other hard-to-nourish cells that have higher or more stringent requirements for the hydrophilicity of the culture surface
Features
Cells can adapt quickly to a serum-free or low-serum culture environment, meeting the needs of experiments that have to eliminate the interference of serum components or that require reduced serum levels, thus saving cost of cell culture



Material

Flask/Plate/Dish Body

Polystyrene (PS)

Flask Cap

High-density Polyethylene (HDPE)

Filter Membrane

Polytetrafluoroethylene (PTFE)

Conforming to USP Class VI standards

Order Information

Cell and Tissue Culture Flasks , Non-treated

Cat. No.Volume(mL)Culture Surface Area(cm²)Maximum Working Volume(mL)Recommended Working Volume(mL)Type of CapLength (mm)Width (mm)Height (mm)SterileQty. Per BagQty. Per Case
CAF0110252512.58.02.5 - 3.8Plug Seal73.740.422.8Y10200
CAF0120252512.58.02.5 - 3.8Vent73.740.422.8Y10200
CAF0110505025.017.55.0 - 7.5Plug Seal92.949.529.1Y10200
CAF0120505025.017.55.0- 7.5Vent92.949.529.1Y10200
CAF01125025075.060.015.0 - 22.5Plug Seal152.581.535.2Y5100
CAF01225025075.060.015.0 - 22.5Vent152.581.535.2Y5100
CAF011600600182.0125.036.4 - 54.6Plug Seal219.3115.738.3Y540
CAF012600600182.0125.036.4 - 54.6Vent219.3115.738.3Y540
CAF111600600182.0 (Extended)200.036.4 - 54.6Plug Seal219.3115.749.5Y540
CAF112600600182.0(Extended)200.036.4 - 54.6Vent219.3115.749.5Y540
CAF011850850300.0200.060.0 - 90.0Plug Seal269.2116.047.0Y318
CAF012850850300.0200.060.0 - 90.0Vent269.2116.027.0Y318

CellATTACH®Cell and Tissue Culture Dishes

Cat. No.Diameter (mm)Height (mm)Recommended Working Volume(mL)Culture Area (cm²)Qty. per BagQty. per Case
CAD0100353512.62-3.58.510240
CAD0100606017.34-721.210240
CAD0100707015.56-1136.310240
CAD0100909016.910-1855.010240
CAD01010010022.612-2060.810240
CAD01015015022.725-50143.0580

CellATTACH®Cell and Tissue Culture Plates

Cat. No.Well Qty.Bottom TypeWell Maximum Working Volume (mL)Well Recommended Working Volume (mL)Qty. Per PackQty. Per Case
CAP0110066Flat17.01.90~2.901100
CAP01101212Flat6.80.76~1.141100
CAP01102424Flat3.50.38~0.571100
CAP01104848Flat1.60.19~0.291100
CAP01109696Flat0.40.08~0.201100
CAP01209696U-shape0.30.08~0.201100

Frequently Asked Questions

What does TC-treated in the product name mean?
TC-treated means that Tissue Cultured is used to treat the surface. By means of corona discharge or gas plasma, Jet Biofil can improve the hydrophilicity of polystyrene (PS) surface, improve the adhesion of proteins needed for cell adhesion, and thus help cells adhere to the wall.
Which surface should I use to culture suspension cells?
The suspension cells do not have the need for cell adhesion, and generally the culture supplies for untreated surface can be used. TC-treated surface can also culture suspension cells, but according to the state and type of cells, some cells may appear adhesion phenomenon.
If I want to coat extracellular matrix myself, what kind of surface should I use?
You can choose the culture vessel with untreated surface to coat the extracellular matrix by yourself. Of course, in this case, vessels with TC-treated surface can also be used
How to use the cell culture bottle with a sealed cap? What are the differences between the use of cell culture bottles with filter membrane caps?
Cell culture bottles with sealed caps provide a closed cell culture environment. If it is needs to connect with the air in the incubator, it is necessary to slightly loosen the cap after the bottle is put into the incubator to allow air to enter. Similarly, when taking out the bottle, tighten the cap first and then take it out. The cap with the filter membrane itself has the function of breathable, and the filter membrane can prevent microbial contamination. Therefore, the cap of the culture bottle can be directly tightened and put into the incubator during use, but it needs to be noted that the filter membrane on the cap cannot be wet, wet filter membrane cannot ensure the passage of gas.
What does T25, T175 mean that I often hear?
Taking T25 as an example, it refers to a cell culture bottle with a growth surface area of 25 cm2. According to the type of bottle cap and different culture surfaces, different article numbers correspond to different products.
I bought the product with article number xxxxxx. What is its growth area? How much medium should I add to culture my cells?
We recommend using 0.2-0.3mL/cm2 of medium
The cell culture bottle/dish I bought is not vacuum packed. The bag looks loose. Is there a quality problem?
The cell culture supplies of Jet Biofil are not vacuum packed, and are only manually aspirated for convenient transportation, so there will be differences. In addition, the temperature and air pressure in different regions will also affect the tightness of the packaging. If there is no air leakage in the package and the cap does not fall off from the product, it will not affect the sterility of the product and the quality of the product. Please feel relieved the use. If the package is damaged or the air leaks or the cover falls off from the product, please take a photo and submit a complaint through your dealer. At the same time, please pay attention to provide a photo of the outer box of the product. When you receive the goods, please carefully confirm whether the outer box is damaged or deformed.
I can’t use up a package of culture supplies in one experiment. How should I preserve it?
We cannot guarantee the sterility of the product after opening. We suggest that you store it in a sterile environment, control the temperature and humidity of the environment, and avoid the storage under light/ultraviolet irradiation.
I used the culture bottle/dish/plate of Jet Biofil, and the cells did not adhere to the wall. Is it a product quality problem?
There are many factors that lead to non-adherent cells, such as culture medium composition and pH value, culture environment, digestion operation, cell type, cell passage, etc. If you use the same product with the same article number to culture the same cell strain for a long time, and the cells adhere normally before, but do not adhere to the wall now, it is recommended that you timely record the batch number of the products used in both cases, and conduct repeated parallel experiments, that is, use cells from the same source to spread on the supplies of these two batches for culture (pay attention to using the culture medium from the same source). Culture in the same incubator to determine the main reason why cells do not adhere to the wall.
The color of the culture bottle/dish/plate I bought this time is more yellow than that of last time. Is it a product quality problem?
It is normal that plastic consumables of different batches may turn yellow after irradiation sterilization.