Phone Number
+91 9108788989
Email
contact@biostarlifetech.com

Bio-Reaction Tubes

Bio-Reaction Tubes

Specification: 15 mL    50 mL   100mL   600 mL
Bottom Type: Conical   Self-standing   Round
Packaging: Foam Rack   Re-sealable Bag 

Product Information

Bio-reaction tubes are suitable for suspension cell and microbial culture, including cell line development, clone selection, medium optimization, and recombinant protein development.
The Jet Biofil Bio-reaction Tubes are made of PP material conforming to USP Class VI standards with defined composition, Animal Derived Component(ADC) Free, good chemical stability, and excellent impact resistance. Equipped with high-quality PVDF/PTFE filter membrane that ensures a sterile environment while ensuring continuous ventilation. Four specifications are available: 15mL, 50mL, 100mL, 600mL, which are suitable for culture and harvest of suspension cell and microbial culture.

Vent cap ensures continuous gas exchange

The white silkscreen printing for labling and recording

360° frosted writing area for labling and recording

600mL Bio-reaction Tubes

Bio-Reaction Tubes Features

Features
The tube body is made of high-quality PP material with defined composition, Animal Derived Component(ADC) Free, good chemical stability, and excellent impact resistance
High-quality PVDF(15mL, 50mL)/PTFE(100mL, 600mL) f ilter membrane that ensures a sterile environment while ensuring continuous ventilation
Four specifications are available: 15mL, 50mL, 100mL, 600mL; Three bottom types are available: conical, self-standing, round
Features
The inner and outer surfaces of the tube are smooth, with uniform thickness and uniform color; the graduations is clear and accurate for easy observation.
Sterilized by irradiation, SAL 10-6
DNase/RNase-free, non-pyrogenic and non-cytotoxic


Material

Tube Body

Polypropylene(PP)

Tube Cap

High-density Polyethylene (HDPE)

Membrane

15mL/50mL: Polyvinylidene Difluoride (PVDF); 100mL/600mL, Polytetrafluoroethylene(PTFE)

Conforming to USP Class VI Standards

Order Information

Bio-Reaction Tubes

Cat. No. Volume (mL) Membrane Bottom Maximum RCF (×g) Sterile Package Qty. Per Bag (Rack) Qty. Per Case
BRT000015 15 PVDF Conical 12,000 Y Re-sealable Bag 10 100
BRT010015 15 PVDF Conical 12,000 Y Foam Rack 50 300
BRT000050 50 PVDF Conical 12,000 Y Re-sealable Bag 10 100
BRT010050 50 PVDF Conical 12,000 Y Foam Rack 25 300
BRT011050 50 PVDF Self-standing 6,000 Y Re-sealable Bag 10 100
BRT010100 100 PTFE Round 6,000 Y Re-sealable Bag 25 300
BRT000600 600 PTFE Conical 6,000 Y Re-sealable Bag 1 32

Bio-Reaction Tubes

Cat. No. Volume (mL) Speciality Sterile Qty. Per Bag Qty. Per Case
BRC000050 50 Tube Cap Y 25 1000

Frequently Asked Questions

What is the maximum rotational speed that the centrifuge tubes of Jet Biofil can withstand?
21000xg. Due to the different center distance of the rotor shaft of different centrifuges, the centrifugal force generated at the same speed (rpm) is also different, so we usually use the relative centrifugal force (RCF) (g) to represent the tolerance degree of the centrifuge tube in the process of rotating centrifugation.
Can the centrifuge tubes of Jet Biofil hold some kind of solution? How about its chemical compatibility?
It is necessary to pay attention to whether the sample is compatible with the material of the centrifuge tube as is used, especially if the sample is some chemical reagents or organic solvents, and the Chemical Compatibility Table of PP Plastic Materials can be used as reference. Samples with low or incompatible centrifugal compatibility are not recommended, and customers can also do pre-experiments to have a test.
What is the possible reason for the burst of the centrifuge tubes in the process of centrifuge?
When centrifuging, it is necessary to pay attention to the chosen centrifugal force cannot exceed the maximum centrifugal force that the product itself can withstand.

Please notice that the maximum centrifugal force (RCF) that can be withstood may be decreased when the sample is centrifuged at low temperature or the sample is an organic solvent/volatile irritant.
What should be pay attention to when using the centrifuge tubes to preserve the samples at a low temperature?
When the sample is preserved below 0 ℃, the applicability of the centrifuge tube is closely related to the composition of the solution and preservation conditions. The centrifuge tube cannot be placed on the foam support, nor the bottom of the tube is in contact with the thermal insulation materials. And please use a hollow support when preserving the samples at low temperature. Otherwise, as part of the centrifuge tube is protected by thermal insulation material, while the other part is not, the temperature difference of the overall tube body makes the tube prone to burst. In addition, please reserve a space of at least 10% of the total volume to avoid sample spillage or tube burst caused by volume expansion due to liquid solidification.
Why the centrifuge tube smell special when its package is opened?
If you smell some odor in the product you receive, it is not because of the abnormal quality of the product. This is because some molecules will be vaporized and retained in the product/packaging in the process of high temperature injection molding/irradiation sterilization of the raw material plastic particles of centrifuge tube products.

The materials used for making the centrifuge tubes of Jet Biofil comply to the USP Class VI standards (USP Class VI Chapter, "Biological reactivity Tests, in Vitro" and Chapter, "Biological Reactivity Tests, in vivo”). No cytolysis or cytotoxic effects were observed through the verification. And the outgoing products in the process of quality inspection have passed various verification tests and are in line with the product release standards.
Call Now Button