Phone Number
+91 9108788989
Email
contact@biostarlifetech.com

Closed System for Erlenmeyer Flasks

Closed System for Erlenmeyer Flasks

Specifications of matching erlenmeyer flask: 125mL   250mL   500mL  1000mL  2L  3L  5L
Type of tube connector: Male MPC connector and MLL connector
Packaging: Three-layer outer medical packaging

Product Information

In the industrial production of biological products, reducing the potential risk of contamination during processes such as liquid transfer and sampling is crucial. Pairing Erlenmeyer flasks with sterile transfer caps and tubing systems can effectively prevent contamination issues associated with open operations.
 
Jet Biofil has introduced a Closed System for large-capacity Erlenmeyer Flasks, made from USP Class VI-compliant materials, manufactured in GMP-standard cleanrooms. The system features extremely low extractable levels and excellent biosafety, making it suitable for fluid transfer processes during the research and production of biologics such as cell therapy, gene therapy, antibodies, and vaccines. After the transfer, the transfer cap can be replaced with ventilate cap to facilitate cell culture, which significantly reduces the risk of contamination and allows for easy, sterile, and secure liquid transfer.


Customization Service


All Close System Solutions can be customized accordingly

MPC connector and MLL connector are available to meet the connection requirements of different types of tubes

The closed transfer system of 5 L erlenmeyer flasks is equipped with a three-way port for sterile sampling

The bottle cap is connected by injection molding to reduce the risk of leakage and residue

The inner tube can extend to the bottom of the bottle to complete liquid transfer. The length and aperture of the tube can also be customized according to requirements

Closed System for Erlenmeyer Flasks Features

Features
The closed transfer system can effectively reduce the risk of contamination in the process of liquid transfer
The medical triple bagged package conforming to higher cleanliness requirement under the GMP production
The bottle cap is connected by injection molding to reduce the risk of leakage and residue
The length and aperture of the tube can also be customized
Sterilized by irradiation, SAL 10-6

Features
Authoritative third-party inspected, products have extremely low extractable levels and excellent biosafety
The inner tube can be extended to the bottom of the bottle to complete liquid transfer
Male MPC connector and MLL connector are available to meet the different types of tube connections
A three-way port for aseptic sampling is available in the 5L closed system, allowing safe and aseptic sampling
DNase/RNase-free, non-pyrogenic, non-cytotoxic

Material

Bottle cap

Polyethylene (PE)

Inner tube

polytetrafluoroethylene (PTFE)

Outer tube

thermoplastic elastomer (TPE)

MLL connector

polypropylene (PP)

MPC connector

Polycarbonate(PC)

Filter housing

polypropylene (PP)

Filter membrane

polytetrafluoroethylene(PTFE)

Conforming to USP Class VI standards

Order Information

Cell and Tissue Culture Flasks , Non-treated

Cell and Tissue Culture Flasks, TC-treated

Cat. No.Volume(mL)Culture Surface Area(cm²)Type of CapRecommended Working Volume(mL)Maximum Working Volume(mL)Length(mm)Width(mm)Height(mm)Botte Neck Diameter(mm)SterileQty. Per BagQty. Per Case
TCF0110252512.5Plug Seal2.5-3.88.073.740.422.814.2Y10200
TCF0120252512.5Vent2.5-3.88.073.740.422.814.2Y10200
TCF0110505025.0Plug Seal5.0-7.517.592.949.529.118.2Y10200
TCF0120505025.0Vent5.0-7.517.592.949.529.118.2Y10200
TCF01125025075.0Plug Seal15.0-22.560.0152.581.535.225.0Y5100
TCF01225025075.0Vent15.0-22.560.0152.581.535.225.0Y5100
TCF011150375150.0 (U-shaped)Plug Seal30.0-45.0140.0199.7111.3111.325.6Y550
TCF022150375150.0 (U-shaped)Vent30.0-45.0140.0199.7111.3111.325.6Y550
TCF011175600175.0Plug Seal35.0-52.5250.0199.9122.749.225.7Y550
TCF012175600175.0Vent35.0-52.5250.0199.9122.749.225.7Y550
TCF011600600182.0Plug Seal36.4-54.6125.0219.3115.738.329.5Y540
TCF012600600182.0Vent36.4-54.6125.0219.3115.738.329.5Y540
TCF111600600182.0 (Extended)Plug Seal36.4-54.6200.0219.3115.749.529.5Y540
TCF112600600182.0 (Extended)Vent36.4-54.6200.0219.3115.749.529.5Y540
TCF011225850225.0Plug Seal60.0-90.0400.0221.9137.249.525.7Y525
TCF012225850225.0Vent60.0-90.0400.0221.9137.249.525.7Y525
TCF011850850300.0Plug Seal60.0-90.0200.0269.2166.047.029.5Y318
TCF012850850300.0Vent60.0-90.0200.0269.2166.047.029.5Y318

CellATTACH® Cell and Tissue Culture Flasks

Cat. No.Volume(mL)Culture Surface Area(cm²)Type of CapMaximum Working Volume(mL)Length(mm)Width(mm)Height(mm)Botte Neck Diameter(mm)SterileQty. Per BagQty. Per Case
TCF0010252512.5Plug Seal8.073.740.422.814.2Y10200
TCF0020252512.5Vent8.073.740.422.814.2Y10200
TCF0010505025.0Plug Seal17.592.949.529.118.2Y10200
TCF0020505025.0Vent17.592.949.529.118.2Y10200
TCF00125025075.0Plug Seal60.0152.581.535.225.0Y5100
TCF00225025075.0Vent60.0152.581.535.225.0Y5100
TCF001150375150.0 (U-shaped)Plug Seal140.0199.7111.3111.325.6Y58
TCF002150375150.0 (U-shaped)Vent140.0199.7111.3111.325.6Y550
TCF001175600175.0Plug Seal250.0199.9122.749.225.7Y550
TCF002175600175.0Vent250.0199.9122.749.225.7Y550
TCF001600600182.0Plug Seal125.0219.3115.738.329.5Y540
TCF002600600182.0Vent125.0219.3115.738.329.5Y540
TCF101600600182.0 (Extended)Plug Seal200.0219.3115.749.529.5Y540
TCF102600600182.0 (Extended)Vent200.0219.3115.749.529.5Y540
TCF001225850225.0Plug Seal400.0221.9137.249.525.7Y525
TCF002225850225.0Vent400.0221.9137.249.525.7Y525
TCF001850850300.0Plug Seal200.0269.2166.047.029.5Y318
TCF002850850300.0Vent200.0269.2166.047.029.5Y318

Frequently Asked Questions

Size information of commonly used microwell plates?
The well plate size of this series conforms to ANSI/SBS well plate size standard, American National Standards Institute (ANSI ) and Society for Biomolecular Sciences (SBS, now affiliated to the Society for Laboratory Automation and Screening ( SLAS))
What is the chemical resistance of microwell plate?
In general, well plates are used for solution and cell culture. If organic solvents are involved, please confirm and verify the well plates according to the specific material of its before use.
What is the range of centrifugal force that the microwell plate can withstand?
We recommend that the centrifugal force not exceed 1,300 g. If there are other treatments affecting the mechanical strength of the well plate before centrifugation, the above suggestions may not be applicable. Please test and verify before use.
Does the deep well plate can be applied to cell culture?
It’s mainly used for sample treatment and preservation. The surface made of polypropylene has not been treated, and we have not tested it for cell culture. So it is recommended that you pre-test for specific applications and conditions before conducting relevant experiments.
Call Now Button