Petri Dishes

Specification: 35 mm 60 mm 70 mm 90 mm 100 mm 150 mm

Product Information

Petri dishes are the most basic and commonly used culture tools in microbiological laboratories for various operations such as inoculation and isolation of bacteria, as well as culturing of fungi, bacteria and other microorganisms. Jet Biofil’s Petri dishes are made from high-quality polystyrene material, offering excellent optical clarity for easy observation of colony morphology. They are available in various sizes to meet the needs of laboratory cultures and automatic media dispenser.

Made of top-quality polystyrene, with even thickness and a smooth surface

High transparency, facilitating optical observation

Petri Dishes Features

Features
Made from high-transparency PS material, with uniform thickness and a flat, smooth bottom for excellent optical clarity
Available in various heights, diameters, and weights to meet different experimental and production needs
Features a positioning ring design for stable stacking of Petri dishes
The inner side of the dish cover is designed for ventilation, allowing gas exchange while ensuring a sterile environment
Features
The 90 mm high-profile Petri dish weighs 15.05 g per unit, allowing stable rotation on a media dispenser carousel
The 90 mm Petri dish without a serrated ring weighs 12.99 g per unit, providing smoother pushing on plate filling production lines
Sterilized by irradiation (SAL 10-6 ) or Aseptic (Manufactured in Class 100,000 cleanrooms) both available
DNase/RNase-free, non-pyrogenic

Material

Polystyrene (PS)

Conforming to USP Class VI Standards

Order Information

Petri Dishes with Serrated Ring

Cat. No. Diameter (mm) Height (mm) Growth Area (cm²) Weight (g) Sanitary Level Qty. Per Bag Qty. Per Case
MCD000060 Φ60 17.3 21.2 8.79 SAL 10⁻⁶ 10 600
MCD000070 Φ70 15.5 36.3 13.74 SAL 10⁻⁶ 10 600
MCD000090 Φ90 16.9 55 20.85 SAL 10⁻⁶ 10 500
MCD000100 Φ100 22.6 60.8 29.45 SAL 10⁻⁶ 10 300

Petri Dishes with Smooth Ring

Cat. No. Diameter (mm) Height (mm) Growth Area (cm²) Weight (g) Sanitary Level Qty. Per Bag Qty. Per Case
MCD000035 Φ35 12.6 8.5 4.11 SAL 10⁻⁶ 10 960
MCD110090 Φ90 15.2 55 12.99 SAL 10⁻⁶ 20 500
MCD111090 Φ90 15.2 55 12.99 SAL 10⁻⁶ 10 500
MCD100090 Φ90 15.2 55 12.99 Aseptic 20 500
MCD000150 Φ150 22.7 143 60.76 SAL 10⁻⁶ 1 120
MCD100150 Φ150 22.7 143 60.76 SAL 10⁻⁶ 5 100

Frequently Asked Questions

What is the maximum rotational speed that the centrifuge tubes of Jet Biofil can withstand?
21000xg. Due to the different center distance of the rotor shaft of different centrifuges, the centrifugal force generated at the same speed (rpm) is also different, so we usually use the relative centrifugal force (RCF) (g) to represent the tolerance degree of the centrifuge tube in the process of rotating centrifugation.
Can the centrifuge tubes of Jet Biofil hold some kind of solution? How about its chemical compatibility?
It is necessary to pay attention to whether the sample is compatible with the material of the centrifuge tube as is used, especially if the sample is some chemical reagents or organic solvents, and the Chemical Compatibility Table of PP Plastic Materials can be used as reference. Samples with low or incompatible centrifugal compatibility are not recommended, and customers can also do pre-experiments to have a test.
What is the possible reason for the burst of the centrifuge tubes in the process of centrifuge?
When centrifuging, it is necessary to pay attention to the chosen centrifugal force cannot exceed the maximum centrifugal force that the product itself can withstand.

Please notice that the maximum centrifugal force (RCF) that can be withstood may be decreased when the sample is centrifuged at low temperature or the sample is an organic solvent/volatile irritant
What should be pay attention to when using the centrifuge tubes to preserve the samples at a low temperature?
When the sample is preserved below 0 ℃, the applicability of the centrifuge tube is closely related to the composition of the solution and preservation conditions. The centrifuge tube cannot be placed on the foam support, nor the bottom of the tube is in contact with the thermal insulation materials. And please use a hollow support when preserving the samples at low temperature. Otherwise, as part of the centrifuge tube is protected by thermal insulation material, while the other part is not, the temperature difference of the overall tube body makes the tube prone to burst. In addition, please reserve a space of at least 10% of the total volume to avoid sample spillage or tube burst caused by volume expansion due to liquid solidification.
Why the centrifuge tube smell special when its package is opened?
If you smell some odor in the product you receive, it is not because of the abnormal quality of the product. This is because some molecules will be vaporized and retained in the product/packaging in the process of high temperature injection molding/irradiation sterilization of the raw material plastic particles of centrifuge tube products.

The materials used for making the centrifuge tubes of Jet Biofil comply to the USP Class VI standards (USP Class VI Chapter, "Biological reactivity Tests, in Vitro" and Chapter, "Biological Reactivity Tests, in vivo”). No cytolysis or cytotoxic effects were observed through the verification. And the outgoing products in the process of quality inspection have passed various verification tests and are in line with the product release standards.
Call Now Button