Phone Number
+91 9108788989
Email
contact@biostarlifetech.com

Robotic Tips

Robotic Tips

Range of tip capacity: 10 μL – 1000 μL
Available configurations: With filter element   Without filter element
Treatment: Non-treated  Low Retention Treated

Color: Natural Black

Product Information

The robotic tips and non-conductive tips are designed for use in robotic pipetting systems and can be used in various liquid handling workstations, such as those produced by Hamilton, Beckman, Tecan and Agilent. They can also be applied to cytomics, genomics, proteomics, immunoassay, metabonomics and the R&D of bio-pharmaceuticals as well as other commonly used high-throughout liquid handling.
 

Standard size and outstanding air tightness

Highly suitability, can be used with all manner of liquid handing workstations

Robotic Tips Features

Features
Made of high quality PP for stable performance
Two types available (with and without filter element) to meet different testing requirements
Exclusive technology—smooth inner surface and excellent concentricity of tips, significantly reducing residues
DNase/RNase-free, non-pyrogenic
Features
Standard size and excellent air tightness
Highly compatibility for use with a wide range of liquid handing workstations
Sterilized by e-beam and passed SGS verification
Sterilized and non-sterilized available, sterilized by irradiation to SAL 10-6

Material

Tip

Polypropylene (PP)

Filter element

Polyethylene(PE)

Conforming to USP Class VI Standards

Order Information

Tecan® Genesis Freedom®, Freedom Evo® and Miniprep with LiHa

Cat. No. Max Volume (µL) Surface Type Sterile Filter Color Package Qty. Per Box Qty. Per Case
ATT10101010NormalYYNaturalRack Box962304
AMT10101010Low RetentionYYNaturalRack Box962304
ATT00002020NormalNNNaturalRack Box962304
AMT00002020Low RetentionNNNaturalRack Box962304
ATT00102020NormalYNNaturalRack Box962304
AMT00102020Low RetentionYNNaturalRack Box962304
ATT00005050NormalNNNaturalRack Box962304
AMT00005050Low RetentionNNNaturalRack Box962304
ATT00105050NormalYNNaturalRack Box962304
AMT00105050Low RetentionYNNaturalRack Box962304
ATT10105050NormalYYNaturalRack Box962304
AMT10105050Low RetentionYYNaturalRack Box962304
ATT000200200NormalNNNaturalRack Box962304
AMT000200200Low RetentionNNNaturalRack Box962304
ATT001200200NormalYNNaturalRack Box962304
AMT001200200Low RetentionYNNaturalRack Box962304
ATT101200200NormalYYNaturalRack Box962304
AMT101200200Low RetentionYYNaturalRack Box962304
ATT0000001000NormalNNNaturalRack Box961536
AMT0000001000Low RetentionNNNaturalRack Box961536
ATT0010001000NormalYNNaturalRack Box961536
AMT0010001000Low RetentionYNNaturalRack Box961536
ATT1010001000NormalYYNaturalRack Box961536
AMT1010001000Low RetentionYYNaturalRack Box961536

Tecan®Genesis Freedom®, Freedom Evo® and Miniprep with LiHa

Cat. No. Max Volume (µL) Surface Type Sterile Filter Color Package Qty. Per Box Qty. Per Case
AUT10101010NormalYYBlackRack Box962304
ANT10101010Low RetentionYYBlackRack Box962304
AUT00002020NormalNNBlackRack Box962304
ANT00002020Low RetentionNNBlackRack Box962304
AUT00102020NormalYNBlackRack Box962304
ANT00102020Low RetentionYNBlackRack Box962304
AUT00005050NormalNNBlackRack Box962304
ANT00005050Low RetentionNNBlackRack Box962304
AUT00105050NormalYNBlackRack Box962304
ANT00105050Low RetentionYNBlackRack Box962304
AUT10105050NormalYYBlackRack Box962304
ANT10105050Low RetentionYYBlackRack Box962304
AUT000200200NormalNNBlackRack Box962304
ANT000200200Low RetentionNNBlackRack Box962304
AUT001200200NormalYNBlackRack Box962304
ANT001200200Low RetentionYNBlackRack Box962304
AUT101200200NormalYYBlackRack Box962304
ANT101200200Low RetentionYYBlackRack Box962304
AUT0000001000NormalNNBlackRack Box961536
ANT0000001000Low RetentionNNBlackRack Box961536
AUT0010001000NormalYNBlackRack Box961536
ANT0010001000Low RetentionYNBlackRack Box961536
AUT1010001000NormalYYBlackRack Box961536
ANT1010001000Low RetentionYYBlackRack Box961536

BECKMAN,FX/NX,Multimek AP96 and Biomek3000

Cat. No. Max Volume (µL) Surface Type Sterile Filter Color Package Qty. Per Box Qty. Per Case
ATB00002020NormalNNNaturalRack Box964800
AMB00002020Low RetentionNNNaturalRack Box964800
ATB00102020NormalYNNaturalRack Box964800
AMB00102020Low RetentionYNNaturalRack Box964800
ATB10102020NormalYYNaturalRack Box964800
AMB10102020Low RetentionYYNaturalRack Box964800
ATB00005050NormalNNNaturalRack Box964800
AMB00005050Low RetentionNNNaturalRack Box964800
ATB00105050NormalYNNaturalRack Box964800
AMB00105050Low RetentionYNNaturalRack Box964800
ATB10105050NormalYYNaturalRack Box964800
AMB10105050Low RetentionYYNaturalRack Box964800
ATB000250250NormalNNNaturalRack Box964800
AMB000250250Low RetentionNNNaturalRack Box964800
ATB001250250NormalYNNaturalRack Box964800
AMB001250250Low RetentionYNNaturalRack Box964800
ATB101180180NormalYYNaturalRack Box964800
AMB101180180Low RetentionYYNaturalRack Box964800

Hamilton STAR, STARlet, STARplus and Nimbus®

Cat. No. Max Volume (µL) Surface Type Sterile Filter Color Package Qty. Per Box Qty. Per Case
ATH00005050NormalNNNaturalRack Box962304
AMH00005050Low RetentionNNNaturalRack Box962304
ATH00105050NormalYNNaturalRack Box962304
AMH00105050Low RetentionYNNaturalRack Box962304
ATH10105050NormalYYNaturalRack Box962304
AMH10105050Low RetentionYYNaturalRack Box962304
ATH000300300NormalNNNaturalRack Box962304
AMH000300300Low RetentionNNNaturalRack Box962304
ATH001300300NormalYNNaturalRack Box962304
AMH001300300Low RetentionYNNaturalRack Box962304
ATH101300300NormalYYNaturalRack Box962304
AMH101300300Low RetentionYYNaturalRack Box962304
ATH0000001000NormalNNNaturalRack Box961536
AMH0000001000Low RetentionNNNaturalRack Box961536
ATH0010001000NormalYNNaturalRack Box961536
AMH0010001000Low RetentionYNNaturalRack Box961536
ATH1010001000NormalYYNaturalRack Box961536
AMH1010001000Low RetentionYYNaturalRack Box961536

Frequently Asked Questions

What is the maximum rotational speed that the centrifuge tubes of Jet Biofil can withstand?
21000xg. Due to the different center distance of the rotor shaft of different centrifuges, the centrifugal force generated at the same speed (rpm) is also different, so we usually use the relative centrifugal force (RCF) (g) to represent the tolerance degree of the centrifuge tube in the process of rotating centrifugation.
Can the centrifuge tubes of Jet Biofil hold some kind of solution? How about its chemical compatibility?
It is necessary to pay attention to whether the sample is compatible with the material of the centrifuge tube as is used, especially if the sample is some chemical reagents or organic solvents, and the Chemical Compatibility Table of PP Plastic Materials can be used as reference. Samples with low or incompatible centrifugal compatibility are not recommended, and customers can also do pre-experiments to have a test.
What is the possible reason for the burst of the centrifuge tubes in the process of centrifuge?
When centrifuging, it is necessary to pay attention to the chosen centrifugal force cannot exceed the maximum centrifugal force that the product itself can withstand.

Please notice that the maximum centrifugal force (RCF) that can be withstood may be decreased when the sample is centrifuged at low temperature or the sample is an organic solvent/volatile irritant
What should be pay attention to when using the centrifuge tubes to preserve the samples at a low temperature?
When the sample is preserved below 0 ℃, the applicability of the centrifuge tube is closely related to the composition of the solution and preservation conditions. The centrifuge tube cannot be placed on the foam support, nor the bottom of the tube is in contact with the thermal insulation materials. And please use a hollow support when preserving the samples at low temperature. Otherwise, as part of the centrifuge tube is protected by thermal insulation material, while the other part is not, the temperature difference of the overall tube body makes the tube prone to burst. In addition, please reserve a space of at least 10% of the total volume to avoid sample spillage or tube burst caused by volume expansion due to liquid solidification.
Why the centrifuge tube smell special when its package is opened?
If you smell some odor in the product you receive, it is not because of the abnormal quality of the product. This is because some molecules will be vaporized and retained in the product/packaging in the process of high temperature injection molding/irradiation sterilization of the raw material plastic particles of centrifuge tube products.

The materials used for making the centrifuge tubes of Jet Biofil comply to the USP Class VI standards (USP Class VI Chapter, "Biological reactivity Tests, in Vitro" and Chapter, "Biological Reactivity Tests, in vivo”). No cytolysis or cytotoxic effects were observed through the verification. And the outgoing products in the process of quality inspection have passed various verification tests and are in line with the product release standards.
Call Now Button