Phone Number
+91 9108788989
Email
contact@biostarlifetech.com

Lid Lock Micro Centrifuge Tubes

Lid Lock Micro Centrifuge Tubes

Specification: 0.5 mL  1.5 mL  2.0 mL  5.0 mL
Packaging: Bag

Product Information

Made of transparent polymer, polypropylene (PP), the centrifuge tubes are designed with a lid lock to provide better sealability for sample protection, and to avoid accidental opening of the cap and evaporation of samples during long-term storage, ensuring safe operations.
 

Designed with a lid lock to avoid accidental opening of thecap

Sharp bottom, smooth, transparent tube and a clear scale, facilitating volume reading

Lid Lock Micro Centrifuge Tubes Features

Features
Multiple volume and color specifications available,easy for recording and identification
Conical bottom, smooth and transparent tube with a clear scale to facilitate volume reading
The tube is designed with a frosted area to record experimental data
DNase/RNase-free, non-pyrogenic
Features
Lid lock prevents accidental opening of cap and evaporation of samples during long-term storage, and ensures safe operations
Maximum RCF of up to 25,000 ×g
Temperature range: -80°C–121°C (does not deform after high-temperature sterilization and remains highly transparent)
Sterilized by irradiation, SAL 10-6

Material

Polypropylene (PP)

Conforming to USP Class VI Standards

Order Information

Micro Centrifuge Tubes with Lid Lock

Cat. No. Capacity (mL) Color Sterile Qty. Per Box Qty. Per Case
CFT0100050.5NaturalN10008000
CFT0100151.5NaturalN5004000
CFT0200151.5BrownN5004000
CFT0100202NaturalN5004000
CFT0110050.5NaturalY10008000
CFT0110151.5NaturalY5004000
CFT0210151.5BrownY5004000
CFT0110202NaturalY5004000

Black Micro Centrifuge Tubes with Lid Lock

Cat. No. Capacity (mL) Color Sterile Qty. Per Box Qty. Per Case
CFT0300050.5BlackN10008000
CFT0300151.5BlackN5004000
CFT0300202BlackN5004000
CFT0310050.5BlackY10008000
CFT0310151.5BlackY5004000
CFT0310202BlackY5004000

Micro Centrifuge Tubes with Lid Lock, Non-sterile, 5 mL

Cat. No. Capacity (mL) Color Sterile Qty. Per Box Qty. Per Case
CFT1220505NaturalN2004000
CFT1230505BlueN2004000
CFT1240505YellowN2004000
CFT1250505GreenN2004000
CFT1260505Rose RedN2004000
CFT1270505BlackN2004000
CFT1100505YellowN2502500
CFT1120505BlackN2502500

Frequently Asked Questions

What is the maximum rotational speed that the centrifuge tubes of Jet Biofil can withstand?
21000xg. Due to the different center distance of the rotor shaft of different centrifuges, the centrifugal force generated at the same speed (rpm) is also different, so we usually use the relative centrifugal force (RCF) (g) to represent the tolerance degree of the centrifuge tube in the process of rotating centrifugation.
Can the centrifuge tubes of Jet Biofil hold some kind of solution? How about its chemical compatibility?
It is necessary to pay attention to whether the sample is compatible with the material of the centrifuge tube as is used, especially if the sample is some chemical reagents or organic solvents, and the Chemical Compatibility Table of PP Plastic Materials can be used as reference. Samples with low or incompatible centrifugal compatibility are not recommended, and customers can also do pre-experiments to have a test.
What is the possible reason for the burst of the centrifuge tubes in the process of centrifuge?
When centrifuging, it is necessary to pay attention to the chosen centrifugal force cannot exceed the maximum centrifugal force that the product itself can withstand.

Please notice that the maximum centrifugal force (RCF) that can be withstood may be decreased when the sample is centrifuged at low temperature or the sample is an organic solvent/volatile irritant
What should be pay attention to when using the centrifuge tubes to preserve the samples at a low temperature?
When the sample is preserved below 0 ℃, the applicability of the centrifuge tube is closely related to the composition of the solution and preservation conditions. The centrifuge tube cannot be placed on the foam support, nor the bottom of the tube is in contact with the thermal insulation materials. And please use a hollow support when preserving the samples at low temperature. Otherwise, as part of the centrifuge tube is protected by thermal insulation material, while the other part is not, the temperature difference of the overall tube body makes the tube prone to burst. In addition, please reserve a space of at least 10% of the total volume to avoid sample spillage or tube burst caused by volume expansion due to liquid solidification.
Why the centrifuge tube smell special when its package is opened?
If you smell some odor in the product you receive, it is not because of the abnormal quality of the product. This is because some molecules will be vaporized and retained in the product/packaging in the process of high temperature injection molding/irradiation sterilization of the raw material plastic particles of centrifuge tube products.

The materials used for making the centrifuge tubes of Jet Biofil comply to the USP Class VI standards (USP Class VI Chapter, "Biological reactivity Tests, in Vitro" and Chapter, "Biological Reactivity Tests, in vivo”). No cytolysis or cytotoxic effects were observed through the verification. And the outgoing products in the process of quality inspection have passed various verification tests and are in line with the product release standards.
Call Now Button