Phone Number
+91 9108788989
Email
contact@biostarlifetech.com

Plastic Centrifuge Tube Racks

Plastic Centrifuge Tube Racks

Compatible Types: PCR Tubes (0.2 mL), Cryogenic Vials (0.5–2 mL), Microcentrifuge Tubes (0.5–5 mL), Centrifuge Tubes (15–50 mL), Conical Centrifuge Bottles (225–600 mL), Bio-reaction tubes (15–600 mL)
Colors: Light Green, Dark Green, White, Blue

Product Information

The centrifuge tube rack securely holds various types of centrifuge containers , effectively preventing sample spillage or tipping to ensure safety and accuracy during experiments. Jet Biofil’s centrifuge tube racks are made of high-quality polypropylene (PP). They are durable, resistant to deformation, and maintain excellent performance even after repeated freeze-thaw cycles and high-temperature, high-pressure sterilization, making them reusable. A wide range of specifications is available to accommodate Jet Biofil centrifuge tubes, microcentrifuge tubes, cryogenic vials, PCR tubes, Bio-reaction tubes, and large-capacity centrifuge bottles, meeting diverse sample handling needs across different laboratory applications.
 

With numerical markings

Smooth-edged design

Stackable

Multi-ribbed reinforced support base

Carrying handles

Plastic Centrifuge Tube Racks Features

Features
Made of high-quality polypropylene (PP) for enhanced durability and strength
Maintains structural integrity after repeated freeze-thaw cycles at -80°C and is autoclavable at 121°C
Surface features numeric or alphanumeric markings for easy identification and experimental record-keeping
Sterilized and non-sterilized available, sterilized by irradiation to SAL 10-6
Microcentrifuge Tube Rack
Dual-sided structure to accommodate 0.2–5.0 mL tubes, providing a total of 186 wells
Smooth-edged design ensures comfortable handling
Available in two specifications: 15 mL and 50 mL, each with 25 wells; offered in four colors
Reinforced multi-ribbed support at the base ensures structural stability
Stackable to save space

Material

Polypropylene (PP)

Conforming to USP Class VI Standards

Order Information

Micro Centrifuge Tube Rack

Cat. No. Applicable Volume (mL) Holes Sterile Color Stackable Qty. Per Bag Qty. Per Case
CTS003001 0.2 30 N Light green Y 1 20
0.5 60
1.5, 2.0 72
5.0 24

Centrifuge Tube Racks

Cat. No. Applicable Volume (mL) Holes Sterile Color Stackable Qty. Per Bag Qty. Per Case
CFR0010151525NLight greenY550
CFR0110151525YLight greenY550
CFR0020151525NDark greenY550
CFR0120151525YDark greenY550
CFR0030151525NWhiteY550
CFR0130151525YWhiteY550
CFR0040151525NBlueY550
CFR0140151525YBlueY550
CFR0010505025NLight greenY550
CFR0110505025YLight greenY550
CFR0020505025NDark greenY550
CFR0120505025YDark greenY550
CFR0030505025NWhiteY550
CFR0130505025YWhiteY550
CFR0040505025NBlueY550
CFR0140505025YBlueY550

Centrifuge Tube Stands

Cat. No. Applicable Volume (mL) Holes Sterile Color Stackable Qty. Per Bag Qty. Per Case
CTS001001 Suitable for 2.0 mL microcentrifuge tube and 15 mL, 50 mL centrifuge tubes 7 N Light green N 1 50
CTS002001 7 Y Light green N 1 50
CTS001002 7 N Light green N 5 50
CTS002002 7 Y Light green N 5 50

Conical Centrifuge Bottle Racks

Cat. No. Applicable Volume (mL) Holes Sterile Color Stackable Qty. Per Bag Qty. Per Case
CTS001225 225, 250 mL 6 N Light green Y 6 12
CTS001500 500 mL 4 N Light green Y 6 12
CTS001600 600 mL 3 N Light green Y 6 12

Frequently Asked Questions

What is the maximum rotational speed that the centrifuge tubes of Jet Biofil can withstand?
21000xg. Due to the different center distance of the rotor shaft of different centrifuges, the centrifugal force generated at the same speed (rpm) is also different, so we usually use the relative centrifugal force (RCF) (g) to represent the tolerance degree of the centrifuge tube in the process of rotating centrifugation.
Can the centrifuge tubes of Jet Biofil hold some kind of solution? How about its chemical compatibility?
It is necessary to pay attention to whether the sample is compatible with the material of the centrifuge tube as is used, especially if the sample is some chemical reagents or organic solvents, and the Chemical Compatibility Table of PP Plastic Materials can be used as reference. Samples with low or incompatible centrifugal compatibility are not recommended, and customers can also do pre-experiments to have a test.
What is the possible reason for the burst of the centrifuge tubes in the process of centrifuge?
When centrifuging, it is necessary to pay attention to the chosen centrifugal force cannot exceed the maximum centrifugal force that the product itself can withstand.

Please notice that the maximum centrifugal force (RCF) that can be withstood may be decreased when the sample is centrifuged at low temperature or the sample is an organic solvent/volatile irritant
What should be pay attention to when using the centrifuge tubes to preserve the samples at a low temperature?
When the sample is preserved below 0 ℃, the applicability of the centrifuge tube is closely related to the composition of the solution and preservation conditions. The centrifuge tube cannot be placed on the foam support, nor the bottom of the tube is in contact with the thermal insulation materials. And please use a hollow support when preserving the samples at low temperature. Otherwise, as part of the centrifuge tube is protected by thermal insulation material, while the other part is not, the temperature difference of the overall tube body makes the tube prone to burst. In addition, please reserve a space of at least 10% of the total volume to avoid sample spillage or tube burst caused by volume expansion due to liquid solidification.
Why the centrifuge tube smell special when its package is opened?
If you smell some odor in the product you receive, it is not because of the abnormal quality of the product. This is because some molecules will be vaporized and retained in the product/packaging in the process of high temperature injection molding/irradiation sterilization of the raw material plastic particles of centrifuge tube products.

The materials used for making the centrifuge tubes of Jet Biofil comply to the USP Class VI standards (USP Class VI Chapter, "Biological reactivity Tests, in Vitro" and Chapter, "Biological Reactivity Tests, in vivo”). No cytolysis or cytotoxic effects were observed through the verification. And the outgoing products in the process of quality inspection have passed various verification tests and are in line with the product release standards.
Call Now Button