Syringe Filters

Syringe Filters

Diameter Specifications: 13 mm  25 mm  30 mm
Membrane Pore Size: 0.1 μm  0.22 μm  0.45 μm
Membrane Type: MCE  Nylon  PVDF  PES  PTFE  CA  SFCA  PES Express

Product Information

Syringe filters, used with disposable syringes, are a fast, convenient and reliable filter processing device routinely used in laboratories for small-volume samples. They are mainly used in pre-filtration of samples, laboratory sterilization and filtration of biological fluids, media and media additives, sample preparation, and gas filtration. JET BIOFIL syringe filters are available in various sizes and membrane configurations for sterile and non-sterile laboratory operations

For use with disposable syringes

Different color outer rings correspond to different membrane types, easy to distinguish and identify

Syringe Filters Features

Features
Single package and bulk packaging are available for different customer requirements
Various membrane types and filtration diameters available
Female Luer connector inlet and male Luer connector outlet
DNase/RNase-free, non-pyrogenic
Features
Polypropylene shell comes with a color ring to distinguish filters of different materials
Each batch undergoes rigorous integrity test
Sterilized and non-sterilized available, sterilized by irradiation to SAL 10-6

Material

Shell

Polypropylene (PP)

Conforming to USP Class VI Standards

Order Information

Syringe Filters, Sterile, Individually Packed

Cat. No. Membrane Material Color Pore Size (μm) Housing Diameter (mm) Sterile Qty / Box Qty / Case
FMC201013MCEYellow0.2213Y100800
FMC201025MCEYellow0.2225Y45360
FMC201030MCEYellow0.2230Y45360
FMC401013MCEYellow0.4513Y100800
FMC401025MCEYellow0.4525Y45360
FMC401030MCEYellow0.4530Y45360
FPV103013PVDFBlue0.1013Y100800
FPV103025PVDFBlue0.1025Y45360
FPV103030PVDFBlue0.1030Y45360
FPV203013PVDFBlue0.2213Y100800
FPV203025PVDFBlue0.2225Y45360
FPV203030PVDFBlue0.2230Y45360
FPV403013PVDFBlue0.4513Y100800
FPV403025PVDFBlue0.4525Y45360
FPV403030PVDFBlue0.4530Y45360
PTF205013PTFEWhite0.2213Y100800
PTF205025PTFEWhite0.2225Y45360
PTF205030PTFEWhite0.2230Y45360
PTF405013PTFEWhite0.4513Y100800
PTF405025PTFEWhite0.4525Y45360
PTF405030PTFEWhite0.4530Y45360
FNY202013NylonPink0.2213Y100800
FNY202025NylonPink0.2225Y45360
FNY202030NylonPink0.2230Y45360
FNY402013NylonPink0.4513Y100800
FNY402025NylonPink0.4525Y45360
FNY402030NylonPink0.4530Y45360
FPE104013PESGreen0.1013Y100800
FPE104025PESGreen0.1025Y45360
FPE104030PESGreen0.1030Y45360
FPE204013PESGreen0.2213Y100800
FPE204025PESGreen0.2225Y45360
FPE204030PESGreen0.2230Y45360
FPE404013PESGreen0.4513Y100800
FPE404025PESGreen0.4525Y45360
FPE404030PESGreen0.4530Y45360
FCA206013CARed0.2213Y100800
FCA206025CARed0.2225Y45360
FCA206030CARed0.2230Y45360
FCA406013CARed0.4513Y100800
FCA406025CARed0.4525Y45360
FCA406030CARed0.4530Y45360
SCA207013SFCADark Blue0.2213Y100800
SCA207025SFCADark Blue0.2225Y45360
SCA207030SFCADark Blue0.2230Y45360
SCA407013SFCADark Blue0.4513Y100800
SCA407025SFCADark Blue0.4525Y45360
SCA407030SFCADark Blue0.4530Y45360
FPE204113PES ExpressGreen0.2213Y100800
FPE204125PES ExpressGreen0.2225Y45360
FPE204130PES ExpressGreen0.2230Y45360
FPE404113PES ExpressGreen0.4513Y100800
FPE404125PES ExpressGreen0.4525Y45360
FPE404130PES ExpressGreen0.4530Y45360
GFA201025GF+CANatural1.1 (GF)+0.22 (CA)25Y45360
GFA201030GF+CANatural1.1 (GF)+0.22 (CA)30Y45360
GFA401025GF+CANatural1.1 (GF)+0.45 (CA)25Y45360
GFA401030GF+CANatural1.1 (GF)+0.45 (CA)30Y45360

Syringe Filters, Sterile, Bulk Packed

Cat. No. Membrane Material Color Pore Size (μm) Housing Diameter (mm) Sterile Qty / Box Qty / Case
FMC211013MCEYellow0.2213Y1001000
FMC211025MCEYellow0.2225Y50500
FMC211030MCEYellow0.2230Y50500
FMC411013MCEYellow0.4513Y1001000
FMC411025MCEYellow0.4525Y50500
FMC411030MCEYellow0.4530Y50500
FPV113013PVDFBlue0.113Y1001000
FPV113025PVDFBlue0.125Y50500
FPV113030PVDFBlue0.130Y50500
FPV213013PVDFBlue0.2213Y1001000
FPV213025PVDFBlue0.2225Y50500
FPV213030PVDFBlue0.2230Y50500
FPV413013PVDFBlue0.4513Y1001000
FPV413025PVDFBlue0.4525Y50500
FPV413030PVDFBlue0.4530Y50500
PTF215013PTFEWhite0.2213Y1001000
PTF215025PTFEWhite0.2225Y50500
PTF215030PTFEWhite0.2230Y50500
PTF415013PTFEWhite0.4513Y1001000
PTF415025PTFEWhite0.4525Y50500
PTF415030PTFEWhite0.4530Y50500
FNY212013NylonPink0.2213Y1001000
FNY212025NylonPink0.2225Y50500
FNY212030NylonPink0.2230Y50500
FNY412013NylonPink0.4513Y1001000
FNY412025NylonPink0.4525Y50500
FNY412030NylonPink0.4530Y50500
FPE214013PESGreen0.2213Y1001000
FPE214025PESGreen0.2225Y50500
FPE214030PESGreen0.2230Y50500
FPE414013PESGreen0.4513Y1001000
FPE414025PESGreen0.4525Y50500
FPE414030PESGreen0.4530Y50500
FCA216013CARed0.2213Y1001000
FCA216025CARed0.2225Y50500
FCA216030CARed0.2230Y50500
FCA416013CARed0.4513Y1001000
FCA416025CARed0.4525Y50500
FCA416030CARed0.4530Y50500
SCA217013SFCADark Blue0.2213Y1001000
SCA217025SFCADark Blue0.2225Y50500
SCA217030SFCADark Blue0.2230Y50500
SCA417013SFCADark Blue0.4513Y1001000
SCA417025SFCADark Blue0.4525Y50500
SCA417030SFCADark Blue0.4530Y50500

Syringe Filters, Non-Sterile, Bulk Packed

Cat. No. Membrane Material Color Pore Size (μm) Housing Diameter (mm) Sterile Qty / Box Qty / Case
FMC221013MCEYellow0.2213N1001000
FMC221025MCEYellow0.2225N50500
FMC221030MCEYellow0.2230N50500
FMC421013MCEYellow0.4513N1001000
FMC421025MCEYellow0.4525N50500
FMC421030MCEYellow0.4530N50500
FPV123013PVDFBlue0.1013N1001000
FPV123025PVDFBlue0.1025N50500
FPV123030PVDFBlue0.1030N50500
FPV223013PVDFBlue0.2213N1001000
FPV223025PVDFBlue0.2225N50500
FPV223030PVDFBlue0.2230N50500
FPV423013PVDFBlue0.4513N1001000
FPV423025PVDFBlue0.4525N50500
FPV423030PVDFBlue0.4530N50500
PTF225013PTFEWhite0.2213N1001000
PTF225025PTFEWhite0.2225N50500
PTF225030PTFEWhite0.2230N50500
PTF425013PTFEWhite0.4513N1001000
PTF425025PTFEWhite0.4525N50500
PTF425030PTFEWhite0.4530N50500
FNY222013NylonPink0.2213N1001000
FNY222025NylonPink0.2225N50500
FNY222030NylonPink0.2230N50500
FNY422013NylonPink0.4513N1001000
FNY422025NylonPink0.4525N50500
FNY422030NylonPink0.4530N50500
FPE224013PESGreen0.2213N1001000
FPE224025PESGreen0.2225N50500
FPE224030PESGreen0.2230N50500
FPE424013PESGreen0.4513N1001000
FPE424025PESGreen0.4525N50500
FPE424030PESGreen0.4530N50500
FCA226013CARed0.2213N1001000
FCA226025CARed0.2225N50500
FCA226030CARed0.2230N50500
FCA426013CARed0.4513N1001000
FCA426025CARed0.4525N50500
FCA426030CARed0.4530N50500
SCA227013SFCADark Blue0.2213N1001000
SCA227025SFCADark Blue0.2225N50500
SCA227030SFCADark Blue0.2230N50500
SCA427013SFCADark Blue0.4513N1001000
SCA427025SFCADark Blue0.4525N50500
SCA427030SFCADark Blue0.4530N50500
PTF225050PTFENatural0.2250N10200
PTF235050PTFENatural0.2250N20240
PTF245050PTFENatural0.2250N1150
PTF255050PTFENatural0.2250N1150
PTF425050PTFENatural0.4550N10200
PTF435050PTFENatural0.4550N20240
PTF445050PTFENatural0.4550N1150
PTF455050PTFENatural0.4550N1150

Frequently Asked Questions

What is the maximum rotational speed that the centrifuge tubes of Jet Biofil can withstand?
21000xg. Due to the different center distance of the rotor shaft of different centrifuges, the centrifugal force generated at the same speed (rpm) is also different, so we usually use the relative centrifugal force (RCF) (g) to represent the tolerance degree of the centrifuge tube in the process of rotating centrifugation.
Can the centrifuge tubes of Jet Biofil hold some kind of solution? How about its chemical compatibility?
It is necessary to pay attention to whether the sample is compatible with the material of the centrifuge tube as is used, especially if the sample is some chemical reagents or organic solvents, and the Chemical Compatibility Table of PP Plastic Materials can be used as reference. Samples with low or incompatible centrifugal compatibility are not recommended, and customers can also do pre-experiments to have a test.
What is the possible reason for the burst of the centrifuge tubes in the process of centrifuge?
When centrifuging, it is necessary to pay attention to the chosen centrifugal force cannot exceed the maximum centrifugal force that the product itself can withstand.

Please notice that the maximum centrifugal force (RCF) that can be withstood may be decreased when the sample is centrifuged at low temperature or the sample is an organic solvent/volatile irritant
What should be pay attention to when using the centrifuge tubes to preserve the samples at a low temperature?
When the sample is preserved below 0 ℃, the applicability of the centrifuge tube is closely related to the composition of the solution and preservation conditions. The centrifuge tube cannot be placed on the foam support, nor the bottom of the tube is in contact with the thermal insulation materials. And please use a hollow support when preserving the samples at low temperature. Otherwise, as part of the centrifuge tube is protected by thermal insulation material, while the other part is not, the temperature difference of the overall tube body makes the tube prone to burst. In addition, please reserve a space of at least 10% of the total volume to avoid sample spillage or tube burst caused by volume expansion due to liquid solidification.
Why the centrifuge tube smell special when its package is opened?
If you smell some odor in the product you receive, it is not because of the abnormal quality of the product. This is because some molecules will be vaporized and retained in the product/packaging in the process of high temperature injection molding/irradiation sterilization of the raw material plastic particles of centrifuge tube products.

The materials used for making the centrifuge tubes of Jet Biofil comply to the USP Class VI standards (USP Class VI Chapter, "Biological reactivity Tests, in Vitro" and Chapter, "Biological Reactivity Tests, in vivo”). No cytolysis or cytotoxic effects were observed through the verification. And the outgoing products in the process of quality inspection have passed various verification tests and are in line with the product release standards.
Call Now Button