SHIELDSKIN™ ORANGE NITRILE™ 300 STERILE

Product Information

  • Orange: Biological risk
  • Protective glove, laboratory glove
  • Category III PPE glove (PPE Directive 89/686/EEC)
  • Complex Design - For mortal and irreversible risks
  • Powder-free orange/white nitrile/polychloroprene glove
  • twin SHIELD™ double-walled protection
  • Ambidextrous
  • 300 mm / 0.14 mm (EN 420:2003 + A1:2009)
  • AQL 0.65 (EN 374-2:2014 Level 3)
  • Viral penetration test (ISO 16604:2004 Procedure B & ASTM F1671-97b)
  • Waterproof and for low chemical protection
  • Tested for chemical permeation (EN 16523-1:2015 supersedes EN 374-3:2003)
  • RNase and DNase free
  • Type I hypersensivity eliminated - Type IV hypersensivity reduced
  • Accelerator free

Additional Data

  • Biocompatibility demonstrated by Buehler and Primary Skin Irritation Tests.
  • Non-detectable levels of chemical allergens using aqueous solution extraction (Phosphate buffered solution)• and High Performance Liquid Chromatography (HPLC) assay method for quantitative analysis.
  • Accelerator-free to minimize the risk of Allergic Contact Dermatitis (also known as Type IV, Delayed• Hypersensitivity or Chemical Allergy).
  • Powder free to minimize the potential consequences of powder-borne dermatitis.
  • Residual powder content is• 1.0 mg/glove (typical) with a limit of 2.0 mg/glove (ISO 21171:2006 “Medical gloves – Determination of removable surface powder”).
  • Micro-organism and virus resistant – passes highest level of micro-organism resistance per EN 374-2:2014• (Performance level 3, AQL < 0.65 and inspection level G1 according to 1000ml water test) and passes viral penetration test using Phi-X174 bacteriophage (ISO 16604:2004 Procedure B & ASTM F1671-97b)
  • Compatible with sterile processing environments due to paperless packaging and multiple post-leaching of gloves. Typical particle levels (per cm² and at > 0.5 μm) are < 3.000 particles
  • Terminally sterilized by gamma irradiation to Sterility Assurance Level (SAL) of 10-6 , in accordance with guidelines detailed in EN ISO 11137-2:2015 “Sterilization of Healthcare Products – Radiation”.
  • Low Endotoxin content at < 20 EU/pair (EN 455-3:2015) demonstrated by Limulus Amoebocyte Lysate (LAL) kinetic turbidimetric test
  • Tested for electrostatic properties according to EN 1149-1/2/3 & 5.
  • Extensively tested for chemical permeation according to EN 16523-1:2015

Technical Data

Characteristics Value Test Method
Freedom from holess <0.65 AQL1 EN374:2003
Tensile Properties Tensile Strength (min) Typical Elongation Ultimate EN 455-2:2015, ASTM D573-04(2015) and ASTM D412-15a
Before Aging 6.0N, min. 7.0N 500%, min.
After Accelerated Aging 6.0N, min. 8.0N 400%, min.
Dimensional Measured Point Mm mil ASTM D3767-03(2014)

EN 420: 2003 + A1: 2009
Nominal Thickness Middle Finger 0.17 6.6
Palm 0.14 5.5
Cuff 0.10 4.0
Length 290mm, min. 300mm, typical

Cleanliness Properties

Particles

Test Method

 

 

Specification

Typical value

 

Particles

Per cm²≥0.5µm

<3.000  particles

2.500 particles

IEST-RP-CC005.4

Ordering Information

SHIELDSKIN XTREME™ STERILE WHITE NITRILE 400 DI+

 

Size

Cat No

Qty

Extra Small (XS/6)

67 6351

20 pouches per sealed PE bag - 8 PE bags per case (160 pairs)

Small (S/7)

67 6352

20 pouches per sealed PE bag - 8 PE bags per case (160 pairs)

Medium (M/8)

67 6353

20 pouches per sealed PE bag - 8 PE bags per case (160 pairs)

Large (L/9)

676354

20 pouches per sealed PE bag - 8 PE bags per case (160 pairs)

Extra Large (XL/10)

676355

20 pouches per sealed PE bag - 8 PE bags per case (160 pairs)

Quality Certification

REGULATORY COMPLIANCE

Whilst process protection is typically the main concern, increasingly users are recognising that there is often an equal need for personal protection of employees from chemicals and biohazards. The responsibilities of the employer are outlined in the PPE at Work Directive 89/656/EEC which is the enshrined in local legislation throughout the European Union (EU). To address this need, all SHIELDskin / SHIELDskin XTREME™ gloves are registered according to the PPE Directive 89/686/EEC.

EXCELLENCE IN ASEPTIC PROCESSING and BIO CONTAMINATION CONTROL

For users of sterile gloves, the SHIELDskin / SHIELDskin XTREME™ gloves offer the highest level of bio contamination control. SHIELD Scientific products provide superior process and personal protection from liquid penetration by micro-organisms (EN 374-2:2014) and viruses (ISO 16604:2004 Procedure B and ASTM F1671-97b). Acceptable Quality Level (AQL) is a crucial parameter for determining barrier properties. An AQL of 0.65 according to EN 374-2:2014 Level 3 represents over 50% less defects than comparable sterile gloves on the market.

Gloves certificates

As a guarantee of industry leading performance, we supply certificates on all our cleanroom gloves. The certificates of conformance (CoC) provide lot-specific data such as levels of particles and extractables, whilst for sterile gloves test data on endotoxin levels is also presented. The certificates of irradiation (CoI) are available for every lot of sterile cleanroom nitrile gloves and sterile cleanroom latex gloves.

Quality Analysis

Material

Proprietary multi-polymer formulation (Acrylonitrile Butadiene with blend of polychloroprene), based on twinSHIELD™ technology. Contains no natural rubber latex

Design

Double barrier protection afforded by orange outer layer combined with white inner-lining. Ambidextrous, beaded cuff and with textured fingertips

AQL

AQL 0.65 ( EN 374-2:2014 Level 3)

Accelerator-free

Minimize the risk of Allergic Contact Dermatitis (also known as Type IV, Delayed Hypersensitivity or Chemical Allergy)

Powder free

Minimize the potential consequences of powder-borne dermatitis. Residual powder content is 1.0 mg/glove (typical) with a limit of 2.0 mg/glove (ISO 21171:2006 “Medical gloves – Determination of removable surface powder”).

Micro-organism and virus resistant

passes highest level of micro-organism resistance per EN 374-2:2014 (Performance level 3, AQL<0.65  and inspection level G1 according to 1000ml water test) and passes viral penetration test using Phi-X 174 bacteriophage (ISO 16604:2004 Procedure B & ASTM F1671-97b

 PPE Category

PPE Category III (Complex Design) according to Council Directive 89/686/EEC.

 

Sterility

Terminally sterilized by gamma irradiation to Sterility Assurance Level (SAL) of 10-6 , in accordance with guidelines detailed in EN ISO 11137-2:2015 “Sterilization of Healthcare Products – Radiation”

 

Endotoxin content

Low End toxin content at <20 EU/pair (EN 455-3:2015) demonstrated by Limulus Amoebocyte Lysate (LAL) kinetic turbidimetric test.

 

Tested for electrostatic properties

Tested for electrostatic Properties according to EN 1149-1/2/3 & 5

 Certification

  Manufactured in accordance with ISO 9001:2015 and ISO 13485:2016

Packing

Packaging designed to comply with sterile processing environments. Gloves pair packed in a sealed polyethylene pouch. Twenty (20) pouches per sealed (double) poly bag. Eight (8) poly bags per double walled shipping case. Total of 160 pairs per outer case.

Satisfaction Guarantee

For users of sterile gloves, the SHIELDskin / SHIELDskin XTREME™ gloves offer the highest level of bio contamination control. SHIELD Scientific products provide superior process and personal protection from liquid penetration by micro-organisms (EN 374-2:2014) and viruses (ISO 16604:2004 Procedure B and ASTM F1671-97b). Acceptable Quality Level (AQL) is a crucial parameter for determining barrier properties. An AQL of 0.65 according to EN 374-2:2014 Level 3 represents over 50% less defects than comparable sterile gloves on the market

Purchase Guarantee

BioStar offers a complete satisfaction guarantee so you can be confident of your purchasing decision. If, for any reason you are not satisfied with the product performance or service provided, we will either replace or issue a refund for the purchase price of your product.

Send us an email for price